The Specular Imaging test targets are tools for objectively assessing the performance of an imaging system

List of readily available BioPixS Specular imaging test targets are specifically designed for biophotonics application imaging applications. They come with unique features tailored to address diverse application like multimodal microscopy, endoscopy and laparoscopy.

Specular imaging test targets

BioPixS offers a range of Specular Imaging test targets with unique features tailored for Biophotonics applications.

Product 1: Multi-purpose negative – high resolution test targets, USAF group 0 to 8

Price: 467€

Tests: USAF, aperture, point spread function, ruler

Multi-purpose negative test target – high resolution, USAF group 0 to 8

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>5

75 x 25 mm

0.5 mm embedded in 1.5 aluminium slide

Beveled

Microscopy, Endoscopy

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Soda lime glass

Min: group 0, element 1. Max: group 8, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)

None

Product 2: Multi-purpose negative – high resolution test targets, USAF group 2 to 8

Price: 289€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Product 2: Multi-purpose negative test target – high resolution, USAF group 2 to 8

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>5

75 x 25 mm

0.5 mm embedded in 1.5 stainless steel slide

Beveled

Microscopy, Endoscopy, Specular Reflection Imaging 

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Soda lime glass

Min: group 2, element 1. Max: group 8, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)

None

Product 3: Multi-purpose negative – low resolution test targets, USAF group -2 to 5

Price: 198€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>3

22x 22 mm

0.18 mm polymer film

Microscopy, Endoscopy

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Polymer

Min: group -2, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)

None

Product 4: Multi-purpose positive – low resolution test targets, USAF group -2 to 5

Price: 198€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>3

22x 22 mm

0.18 mm polymer film

Microscopy, Endoscopy

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Polymer

Min: group -2, element 1. Max: group 5, element 6

10-20

Positive

USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)

None

Product 5: Multi-purpose negative – low resolution test targets, USAF group 0 to 5

Price: 149€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Multi-purpose negative test target – low resolution, USAF group 0 to 5

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>3

22x 22 mm

0.18 mm polymer film

Microscopy, Endoscopy, Imaging, Specular Reflection Imaging

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Polymer

Min: group 0, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)

None

Product 6: Multi-purpose positive – low resolution test targets, USAF group 0 to 5

Price: 149€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Multi-purpose positive test target – low resolution, USAF group 0 to 5

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:

>3

22x 22 mm

0.18 mm polymer film

Microscopy, Endoscopy, Imaging, Specular Reflection Imaging

None

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:

Polymer

Min: group 0, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)

None

Why Specular Imaging test targets

  • Expertise that Matters: The rich experience of BioPixS in biophotonics imaging technology enables precision designs tailored for wide range of biophotonics applications.

  • Diverse Catalogue: Explore the wide range of test targets and unique combination of multimodal test targets to address diverse multimodal imaging applications in biophotonics.

  • Customization Beyond Limits: Beyond off-the-shelf products available here, we provide OEM product customization solutions to address specific needs of biomedical optics industry.


Experience unparalleled excellence in optical resolution assessments with our multi-test targets, meticulously crafted to elevate your imaging system capabilities.