The fluorescence test targets are embedded in fluorescence phantom material, covering a wide range of fluorophores and optical properties that mimic human tissue.

They come with unique features tailored to address diverse applications like multimodal microscopy, FLIM, and fluorescence surgical guidance system.

Fluorescence test targets

BioPixS offers a range Fluorescence Imaging test targets with unique features tailored for Biophotonics applications.

Product 1: Multi-purpose negative – high resolution test targets, USAF group 0 to 8

Price: 667€

Tests: USAF, aperture, point spread function, ruler

Multi-purpose negative test target – high resolution, USAF group 0 to 8

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>5

75 x 25 mm

0.5 mm embedded in 1.5 stainless steel slide

Beveled

Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Soda lime glass

Min: group 0, element 1. Max: group 8, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1μ s‘= 10 cm -1)

1.5

Product 2: Multi-purpose negative – high resolution test targets, USAF group 2 to 8

Price: 489€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Product 2: Multi-purpose negative test target – high resolution, USAF group 2 to 8

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>5

75 x 25 mm

0.5 mm embedded in 1.5 stainless steel slide

Beveled

Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging system  

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Soda lime glass

Min: group 2, element 1. Max: group 8, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1, μ s‘= 10 cm -1)

1.5

Product 3: Multi-purpose negative – low resolution test targets, USAF group -2 to 5

Price: 398€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>3

22x 22 mm

0.18 mm polymer film

Hybrid fluorescence hyperspectral imaging, Endoscopy, surgical guidance and other imaging systems

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Polymer

Min: group -2, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1, μ s‘= 10 cm -1)

1.5

Product 4: Multi-purpose positive – low resolution test targets, USAF group -2 to 5

Price: 398€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>3

22x 22 mm

0.18 mm polymer film

Hybrid fluorescence hyperspectral imaging, Endoscopy, surgical guidance and other imaging systems

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Polymer

Min: group -2, element 1. Max: group 5, element 6

10-20

Positive

USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1, μ s‘= 10 cm -1)

1.5

Product 5: Multi-purpose negative – low resolution test targets, USAF group 0 to 5

Price: 349€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Multi-purpose negative test target – low resolution, USAF group 0 to 5

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>3

22x 22 mm

0.18 mm polymer film

Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Polymer

Min: group 0, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1, μ s‘= 10 cm -1)

1.5

Product 6: Multi-purpose positive – low resolution test targets, USAF group 0 to 5

Price: 349€

Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler

Multi-purpose positive test target – low resolution, USAF group 0 to 5

Optical density:

Dimensions:

Thickness:

Edges:

Application:

Backing material:


Backing material thickness:

>3

22x 22 mm

0.18 mm polymer film

Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems

Fluorescence material or fluorescence phantom


1.5-3 mm

Substrate:

Resolution:

Surface quality:

Type:

Test:

Backing material prop.:


Backing material refractive index:

Polymer

Min: group 0, element 1. Max: group 5, element 6

10-20

Negative

USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)

General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ a= 0.1 cm -1, μ s‘= 10 cm -1)

1.5

Why choose Fluorescence test targets

  • Expertise that Matters: The long standing experience of BioPixS team and collaborators provide the test target with unique features that are critical for biophotonics imaging applications. For example, co-location of alignment markers with resolution test target allows for creating overlays in multimodal imaging systems.

  • Customization Beyond LimitsWe are open to listen to your needs. Our experienced team will customize test targets for your application requirements. We are one stop solution to meet all your OEM test target needs.

  • Wide selection catalogue: we provide broad range of backing material mimicking various fluorophores in visible-NIR region making it a one stop solution for your fluorescence phantom needs.


Immerse yourself in exceptional proficiency in optical resolution evaluations with our fluorescence test targets,for a comprehensive imaging experience!