The fluorescence test targets are embedded in fluorescence phantom material, covering a wide range of fluorophores and optical properties that mimic human tissue.
They come with unique features tailored to address diverse applications like multimodal microscopy, FLIM, and fluorescence surgical guidance system.
BioPixS offers a range Fluorescence Imaging test targets with unique features tailored for Biophotonics applications.
Price: 1498€
Tests: USAF, aperture, point spread function, ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>5
75 x 25 mm
0.5 mm embedded in 1.5 stainless steel slide
Beveled
Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Soda lime glass
Min: group 0, element 1. Max: group 8, element 6
10-20
Negative
USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Price: 489€
Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>5
75 x 25 mm
0.5 mm embedded in 1.5 stainless steel slide
Beveled
Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging system
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Soda lime glass
Min: group 2, element 1. Max: group 8, element 6
10-20
Negative
USAF, aperture, PSF, annotated Ronchi ruling (1, 10, 100 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Price: 948€
Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>3
22x 22 mm
0.18 mm polymer film
–
Hybrid fluorescence hyperspectral imaging, Endoscopy, surgical guidance and other imaging systems
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Polymer
Min: group -2, element 1. Max: group 5, element 6
10-20
Negative
USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Price: 948€
Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>3
22x 22 mm
0.18 mm polymer film
–
Hybrid fluorescence hyperspectral imaging, Endoscopy, surgical guidance and other imaging systems
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Polymer
Min: group -2, element 1. Max: group 5, element 6
10-20
Positive
USAF, aperture, PSF, annotated Ronchi ruling (1, 5 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Price: 349€
Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>3
22x 22 mm
0.18 mm polymer film
–
Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Polymer
Min: group 0, element 1. Max: group 5, element 6
10-20
Negative
USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Price: 349€
Tests: USAF, alignment crosswire, aperture, point spread function, annotated Ronchi ruler
Optical density:
Dimensions:
Thickness:
Edges:
Application:
Backing material:
Backing material thickness:
>3
22x 22 mm
0.18 mm polymer film
–
Multimodal microscopy, Fluorescence microscopy, Endoscopy, surgical guidance and other imaging systems
Fluorescence material or fluorescence phantom
1.5-3 mm
Substrate:
Resolution:
Surface quality:
Type:
Test:
Backing material prop.:
Backing material refractive index:
Polymer
Min: group 0, element 1. Max: group 5, element 6
10-20
Negative
USAF, aperture, PSF, crosswire, annotated Ronchi ruling (1, 5 lines/mm)
General fluorescence agents in VIS-NIRS.
ICG mimicking fluorophores will be embedded in optical phantom (μ
a= 0.1 cm
-1, μ
s‘= 10 cm
-1)
1.5
Why choose Fluorescence test targets
- Expertise that Matters: The long standing experience of BioPixS team and collaborators provide the test target with
unique features that are critical for biophotonics imaging applications. For example, co-location of alignment markers with resolution test target allows for creating overlays in multimodal imaging systems.
- Customization Beyond Limits: We are open to listen to your needs. Our experienced team will customize test targets
for your application requirements. We are one stop solution to meet all your OEM test target needs.
- Wide selection catalogue: we provide broad range of backing material mimicking various fluorophores in visible-NIR region making it a one stop solution for your fluorescence phantom needs.
- Fluoresce Lifetime Imaging (FLIM): in addition to intensity-based fluorescence test targets, BioPixS also provides Fluorescence Lifetime Imaging (FLIM) test targets, specifically developed for systems that rely on fluorescence lifetime contrast. These targets incorporate dyes with well-characterized lifetimes, enabling:
- Accurate calibration and validation of FLIM systems.
- Quantitative comparison between different imaging setups.
- Benchmarking of analysis algorithms for lifetime extraction.
- Training and education, offering users stable, reproducible standards.
Our FLIM test targets are available in both Low Resolution and High Resolution versions, ensuring flexibility for diverse applications.
Immerse yourself in exceptional proficiency in optical resolution evaluations with our fluorescence test targets,for a comprehensive imaging experience!